[version 12][version 11][version 10][version 9][version 8][version 7][version 6]
4.4 Time and data input/output control
The OpenFOAM solvers begin all runs by setting up a database. The database controls I/O and, since output of data is usually requested at intervals of time during the run, time is an inextricable part of the database. The controlDict dictionary sets input parameters essential for the creation of the database. The keyword entries in controlDict are listed in the following sections. Only the time control and writeInterval entries are mandatory, with the database using default values for any of the optional entries that are omitted. Example entries from a controlDict dictionary are given below:
16 17application foamRun; 18 19solver incompressibleFluid; 20 21startFrom latestTime; 22 23startTime 0; 24 25stopAt endTime; 26 27endTime 0.3; 28 29deltaT 0.0001; 30 31writeControl adjustableRunTime; 32 33writeInterval 0.01; 34 35purgeWrite 0; 36 37writeFormat ascii; 38 39writePrecision 6; 40 41writeCompression off; 42 43timeFormat general; 44 45timePrecision 6; 46 47runTimeModifiable yes; 48 49adjustTimeStep yes; 50 51maxCo 5; 52 53// ************************************************************************* //
4.4.1 Modules
solver-
Choice of solver module for the simulation, e.g. incompressibleFluid
regionSolvers-
Dictionary of solvers for different domain regions, e.g. heat transfer of water flowing over a plate might use the fluid and solid modules as follows:
regionSolvers
{
water fluid;
plate solid;
}
libs-
List of additional libraries (existing on $LD_LIBRARY_PATH) to be loaded at run-time, e.g. ("libNew1.so" "libNew2.so")
4.4.2 Time control
startFrom-
Controls the start time of the simulation.
startTime-
Start time for the simulation with startFrom startTime;
stopAt-
Controls the end time of the simulation.
endTime-
End time for the simulation when stopAt endTime; is specified.
deltaT-
Time step of the simulation.
4.4.3 Data writing
writeControl-
Controls the timing of write output to file.
-
runTime: Writes data every writeInterval seconds of simulated time.
-
adjustableRunTime: Writes data every writeInterval seconds of simulated time, adjusting the time steps to coincide with the writeInterval if necessary — used in cases with automatic time step adjustment.
-
cpuTime: Writes data every writeInterval seconds of CPU time.
-
clockTime: Writes data out every writeInterval seconds of real time.
writeInterval-
Scalar used in conjunction with writeControl described above.
purgeWrite-
Integer representing a limit on the number of time directories that are stored by overwriting time directories on a cyclic basis. For example, if the simulations starts at = 5s and = 1s, then with purgeWrite 2;, data is first written into 2 directories, 6 and 7, then when 8 is written, 6 is deleted, and so on so that only 2 new results directories exists at any time. To disable the purging, specify purgeWrite 0; (default).
writeFormat-
Specifies the format of the data files.
writePrecision-
Integer used in conjunction with writeFormat described above, 6 by default.
writeCompression-
Switch to specify whether files are compressed with gzip when written: on/off (yes/no, true/false)
timeFormat-
Choice of format of the naming of the time directories.
timePrecision-
Integer used in conjunction with timeFormat described above, 6 by default.
graphFormat-
Format for graph data written by an application.
4.4.4 Other settings
beginTime-
Optional entry to for cases with an unusual start time that causes inconvenient write times. With beginTime, the write times are multiples of writeInterval, starting at the beginTime. For example, if the start time of 1.52 and a writeInterval of 1, results would be written at 2.52, 3.52, …If beginTime is set to 0 (or 1), the write times would be 2, 3, etc.
Switch used by some solvers to adjust the time step during the simulation, usually according to maxCo.
adjustTimeStep-
Switch used by some solvers to adjust the time step during the simulation, usually according to maxCo.
maxCo-
Maximum Courant number, e.g. 0.5
runTimeModifiable-
Switch for whether dictionaries, e.g.controlDict, are re-read during a simulation at the beginning of each time step, allowing the user to modify parameters during a simulation.
functions-